Measurement and Instrumentation MCQ Multiple Choice Questions - Page 2 for Practice

31. For measurements on high voltage capacitors, the suitable bridge is

32. For measuring a very high resistance we should use

33. For measuring current at high frequency we should use

34. If an inductance is connected in one arm of bridge and resistances in the remaining three arms

35. If an instrument has cramped scale for larger values, then it follows

36. If the current in a capacitor leads the voltage by 80°, the loss angle of the capacitor is

37. In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be

38. In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was

39. In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at

40. In a low power factor wattmeter the compensating coil is connected

41. In a low power factor wattmeter the pressure coil is connected

42. In a meggar controlling torque is provided by

43. In a portable instrument, the controlling torque is provided by

44. In a Schering bridge the potential of the detector above earth potential is

45. In a single phase power factor meter the phase difference between the currents in the two pressure coils is

46. In a vibrating reed frequency meter the natural frequencies of two adjacent reeds have a difference of

47. In a Weston frequency meter, the magnetic axes of the two fixed coils are

48. In a Weston synchronoscope, the fixed coils are connected across

49. In an AC. co-ordinate potentiometer, the currents in the phase and quadrature potentiometer are adjusted to be

50. In an Anderson bridge, the unknown inductance is measured in terms of

51. In an energymeter braking torque is produced to

52. In majority of instruments damping is provided by

53. In order to achieve high accuracy, the slide wire of a potentiometer should be

54. In Weston synchronoscope the moving coil is connected across

55. Induction type single phase energy meters measure electric energy in

56. Instrument transformers are

57. is an instrument which measures the insulation resistance of an electric circuit relative to earth and one another

58. It is required to measure the true open circuit e.m.f. of a battery. The best device is

59. Most common form of A.C. meters met with in every day domestic and industrial installations are

60. Most sensitive galvanometer is